Revista de Odontologia da UNESP
https://revodontolunesp.com.br/article/doi/10.1590/1807-2577.11119
Revista de Odontologia da UNESP
Original Article

Evaluation of degradation of force of esthetic elastomeric chains

Avaliação da degradação de força de correntes elastoméricas estéticas

Mayra Teixeira Cortat LUCINDO; Diego Patrik Alves CARNEIRO; Felipe Alexandre de SOUZA; Américo Bortolazzo CORRER; Heloisa Cristina VALDRIGHI

Downloads: 0
Views: 443

Abstract

Abstract: Introduction: Elastomers are considered important allies to orthodontic treatment and due to the aesthetic demand, aesthetic elastomers are increasingly used in adult patients.

Objective: The aim of this experimental in vitro study was to evaluate the degradation of force of esthetic elastomeric chains, of three different sizes: short, medium and long.

Material and method: For evaluating the degradation of force, 90 elastomeric chain segments were used, divided into 9 Groups (n=10), as follows: Morelli short elastomer, Morelli medium, Morelli long, Orthometric short, Orthometric medium, Orthometric long, American Orthodontic short, American Orthodontic medium and American Orthodontic long. Acrylic plates with pins were used to provide stretching of the elastomeric chains. The initial stretching force of the elastomeric chain was 150 grams, measured by a tensiometer. After this, they were prestretched to 50% of their original length, measured in an Instron 4411 Universal test machine, and placed on the seating pin on the plate. The plate was immersed in artificial saliva at 37 °C in a plastic receptacle, and removed for measurement after a time interval of 21 days. For statistical analysis, the methodology of mixed models for repeated measures in time and Tukey-Kramer test were used. Degradation of the forces was analyzed by 2-way analysis of variance (ANOVA) and the Tukey test.

Result: All the elastomeric chains showed statistically significant reduction in force (p<0.05). The American Orthodontic elastomeric chains showed higher reduction in force values, irrespective of the elastic size (p<0.05).

Conclusion: The three commercial brands studied underwent significant reduction in the quantity of force released; the American Orthodontic brand of elastomer showed the highest value of degradation in force.

Keywords

Orthodontics, elastomers, elastic modulus, dental esthetics

Resumo

Resumo: Introdução: Os elastômeros são considerados aliados importantes do tratamento ortodôntico e, devido à demanda estética, os elastômeros estéticos são cada vez mais utilizados em pacientes adultos.

Objetivo: O objetivo desse estudo experimental in vitro foi avaliar a degradação de forças geradas pelas cadeias elastoméricas estéticas, em três diferentes tamanhos curto, médio e longo.

Material e método: Para a avaliação da degradação da força foram utilizados 90 segmentos de cadeias elastoméricas, divididos em 9 grupos (n=10), sendo: elastômero Morelli curto, Morelli médio, Morelli longo, Orthometric curto, Orthometric médio, Orthometric longo, American Orthodontic curto, American Orthodontic médio e American Orthodontic longo. Foram utilizadas placas de acrílico com pinos que proporcionaram o estiramento das cadeias elastoméricas. A força inicial de estiramento da cadeia elastomérica foi de 150 gramas, medidas por um tensiômetro. Em seguida foram pré-estiradas em 50% do seu comprimento original, medidas em uma máquina Universal Instron 4411 e levadas ao pino de assentamento na placa. A placa foi imersa em um recipiente plástico com saliva artificial a 37 °C e removida após 21 dias para aferição. Foi aplicada metodologia de modelos mistos para medidas repetidas no tempo e teste de Tukey-Kramer. A degradação das forças foi analisada por análise de variância (ANOVA) “2 fatores” e teste de Tukey.

Resultado: Todas as correntes elastoméricas apresentaram redução estatisticamente significativa da força (p<0,05). As correntes elastoméricas da American Orthodontic apresentaram maior redução de força, independentemente do tamanho do elástico (p<0,05).

Conclusão: As três marcas comerciais estudadas sofreram uma redução significativa na quantidade de força liberada, sendo o elastômero da marca American Orthodontic o que apresentou maior degradação de força.
 

Palavras-chave

Ortodontia, elastômeros, módulo elástico, estética dentária

References

1 Martins MM, Lima TA, Soares CMO. Influência do pré-estiramento nas forças geradas por elásticos ortodônticos em cadeia. Cienc Odontol Bras. 2008 Jul;11(3):38-46.

2 Yagura D, Baggio PE, Carreiro LS, Takahashi R. Deformation of elastomeric chains related to the amount and time of stretching. Dental Press J Orthod. 2013 May-Jun;18(3):136-42. http://dx.doi.org/10.1590/S2176-94512013000300022. PMid:24094024.

3 Fernandes AB, Ribeiro AA, Araujo MV, Ruellas AC. Influence of exogenous pigmentation on the optical properties of orthodontic elastic ligatures. J Appl Oral Sci. 2012 Jul-Aug;20(4):462-6. http://dx.doi.org/10.1590/S1678-77572012000400012. PMid:23032209.

4 Almudhi AA, Talic NF. The effect of dietary pigmentation on the esthetic appearance of clear orthodontic elastomeric modules. J Orthod Sci. 2016 Apr-Jun;5(2):70-3. http://dx.doi.org/10.4103/2278-0203.179418. PMid:27127754.

5 Masoud AI, Tsay TP, BeGole E, Bedran-Russo AK. Force decay evaluation of thermoplastic and thermoset chains: a mechanical desing comparison. Angle Orthod. 2014 Nov;84(6):1026-33. http://dx.doi.org/10.2319/010814-28.1. PMid:24784844.

6 Quenzer JP, Lucato AS, Vedovello SAS, Valdrighi HC, Vedovello M Fo. Influence of elastic chain in the degradation of orthodontic forces: in vitro study. Rev Odontol UNESP. 2015 Dec;44(6):320-5. http://dx.doi.org/10.1590/1807-2577.0075.

7 Santos ACS, Tortamano A, Naccarato SRF, Dominguez-Rodriguez GC, Vigorito JW. An in vitro comparison of the force decay generated by different commercially available elastomeric chains and NiTi closed coil springs. Braz Oral Res. 2007 Mar;21(1):51-7. http://dx.doi.org/10.1590/S1806-83242007000100009. PMid:17384855.

8 Rembowski Casaccia G, Gomes JC, Alviano DS, de Oliveira Ruellas AC, Sant’Anna EF. Microbiological evaluation of elastomeric chains. Angle Orthod. 2007 Sep;77(5):890-3. http://dx.doi.org/10.2319/091106-367. PMid:17685763.

9 Nakhaei S, Agahi RH, Aminian A, Rezaeizadeh M. Discoloration and force degradation of orthodontic elastomeric ligatures. Dental Press J Orthod. 2017 Mar-Apr;22(2):45-54. http://dx.doi.org/10.1590/2177-6709.22.2.045-054.oar. PMid:28658355.

10 Balhoff DA, Shuldberg M, Hagan JL, Ballard RW, Armbruster PC. Force decay of elastomeric chains: a mechanical design and product comparison study. J Orthod. 2011 Mar;38(1):40-7. http://dx.doi.org/10.1179/14653121141227. PMid:21367827.

11 Weissheimer A, Locks A, Menezes LM, Borgatto AF, Derech CDA. In vitro evaluation of force degradation of elastomeric chains used in orthodontics. Dental Press J Orthod. 2013 Jan-Feb;18(1):55-62. http://dx.doi.org/10.1590/S2176-94512013000100014. PMid:23876950.

12 Fernandes AB, Ruellas AC, Araújo MV, Sant’Anna EF, Elias CN. Assessment of exogenous pigmentation in colourless elastic ligatures. J Orthod. 2014 Jun;41(2):147-51. http://dx.doi.org/10.1179/1465313313Y.0000000083. PMid:24521746.

13 Alexandre LP, Oliveira G Jr, Dressano D, Paranhos LR, Scanavini MA. Avaliação das propriedades mecânicas dos elásticos e cadeias elastoméricas em ortodontia. Rev Odonto. 2008 Jul-Dez;16(32):53-63. http://dx.doi.org/10.15603/2176-1000/odonto.v16n32p53-63.

14 Kochenborger C, Silva DL, Marchioro EM, Vargas DA, Hahn L. Assessment of force decay in orthodontic elastomeric chains: an in vitro study. Dental Press J Orthod. 2011 Dec;16(6):93-9. http://dx.doi.org/10.1590/S2176-94512011000600015.

15 Aldrees AM, Al-Foraidi AS, Murayshed MS, Almoammar KA. Color stability and force decay of clear orthodontic elastomeric chains: an in vitro study. Int Orthod. 2015 Sep;13(3):287-301. http://dx.doi.org/10.1016/j.ortho.2015.06.003. PMid:26277455.

16 Zaniboni E, Vedovello M Fo, Santamaria MP, Jardini MAN, Martins-Ortiz MF, Consolaro A, et al. Root morphology can be a risk fator for periodontal damage and root resorption in Orthodontic movement. Braz J Oral Sci. 2017;16:1-8. http://dx.doi.org/10.20396/bjos.v16i0.8651188.

17 Baratieri C, Mattos CT, Alves M Jr, Lau TC, Nojima LI, de Souza MM, et al. In situ evaluation of orthodontic elastomeric chains. Braz Dent J. 2012;23(4):394-8. http://dx.doi.org/10.1590/S0103-64402012000400014. PMid:23207855.

18 Omidkhoda M, Rashed R, Khodarahmi N. Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains. Dent Res J. 2015 Jul-Aug;12(4):348-52. http://dx.doi.org/10.4103/1735-3327.161453. PMid:26288625.

19 Behnaz M, Namvar F, Sohrabi S, Parishanian M. Effect of bleaching mouthwash on force decay of orthodontic elastomeric chains. J Contemp Dent Pract. 2018 Feb;19(2):221-5. http://dx.doi.org/10.5005/jp-journals-10024-2240. PMid:29422474.
 

5e3d9ccb0e8825e24a4adb1b rou Articles
Links & Downloads

Rev. odontol. UNESP

Share this page
Page Sections