Influence of metal bar lever-arm on screws detorque for dental prosthesis implant supported
Influência do cantilever no destorque de parafusos de barras metálicas utilizadas em próteses do tipo protocolo de Brannemark
Wilson MATSUMOTO; Ana Paula MACEDO; Rossana Pereira de ALMEIDA; Anselmo Agostinho SIMIONATO; Takami Hirono HOTTA
Abstract
Keywords
Resumo
Resumo:
Palavras-chave
References
1 Misch CE. Dental implant prosthetics. 2nd ed. St. Louis: Elsevier; 2015. 993 p.
2 Koyano K, Esaki D. Occlusion on oral implants: current clinical guidelines. J Oral Rehabil. 2015 Feb;42(2):153-61.
3 Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981 Dec;10(6):387-416.
4 Drago C. Cantilever lengths and anterior-posterior spreads of interim, acrylic resin, full-arch screw-retained prosthesis and their relationship to prosthetic complications. J Prosthodont. 2017 Aug;26(6):502-7.
5 Kreissl M, Gerds T, Muche R, Heydecke G, Strub JR. Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an anverage observation period of 5 years. Clin Oral Implants Res. 2007 Dec;18(6):720-6.
6 Pjetursson BE, Zarauz C, Strasding M, Sailer I, Zwahlen M, Zembic A. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res. 2018 Oct;29(Suppl 18):160-83.
7 Bacchi A, Consani RLX, Mesquita MF, Santos MBF. Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with diferente framework materials and vertical misfit levels: a three-dimensional finite element analysis. J Oral Sci. 2013;55(3):239-44.
8 Dixon DL, Breeding L, Sadler JP, Mckay ML. Comparison of screw loosening, rotation, and deflection among three implant design. J Prosthet Dent. 1995 Sep;74(3):270-8.
9 Bhering CLB, Takahashi JMFK, Luthi LF, Henriques GEP, Consani RLX, Mesquita MF. Influence of the casting technique and dynamics loading on screw detorque and misfit of single unit implant-supported prostheses. Acta Odontol Scand. 2013 May-Jul;71(3-4):404-9.
10 Nissan J, Gross M, Shifman A, Assif D. Stress levels for well-fitting implant superstructures as a function of tightening force levels, tightening sequence, and different operators. J Prosthet Dent. 2001 Jul;86(1):20-3.
11 Farina AP, Spazzin AO, Consani RLX, Mesquita MF. Screw Joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions. J Prosthet Dent. 2014 Jun;111(6):499-504.
12 Suedam V, Souza EA, Moura MS, Jacques LB, Rubo JH. Effect of abutment’s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin Oral Implants Res. 2009 Feb;20(2):196-200.
13 Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the strss distribuition of mandibular-cantilevered implant-supported prostheses. Clin Oral Implants Res. 2009 jul;20(7):737-41.
14 Siamos G, Winkler S, Boberick K. The relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol. 2002;28(2):67-73.
15 Walter L, Greenstein G. Utility of measuring anterior-posterior spread to determine distal cantilever length off a fixed implant-supported full-arch prosthesis: a review of the literature. J Am Dent Assoc. 2020;151(10):790-5.
16 Medeiros RA, Goiato MC, Pesqueira AA, Vechiato AJ Fo, Bonatto LD, Santos DM. Stress distribution in an implant-supported mandibular complete denture using different cantilever lengths and occlusal coating materials. Implant Dent. 2017 Feb;26(1):106-11.
17 Cid RMO, Stanley K, Cordero EB, Benfatti CAM, Bianchini MA. Influence of cantilever length and type of arch antagonist on bone loss in total implant-supported prosthesis. Acta Odontol Latinoam. 2014;27(3):131-6. http://dx.doi.org/10.1590/S1852-48342014000300006. PMid:25560692.
18 Hanif A, Qureshi S, Sheikh Z, Rashid H. Complications in implant dentistry. Eur J Dent. 2017 Jan-Mar;11(1):135-40.
19 Pereira J, Morsch CS, Henriques B, Nascimento RM, Benfatti CA, Silva FS, et al. Removal torque and biofilm accumulation at two dental implant-abutment joints after fatigue. Int J Oral Maxillofac Implants. 2016 Jul-Aug;31(4):813-9.
20 Cantwell A, Hobkirk JA. Preload loss in gold prosthesis-retaining screws as a function of time. Int J Oral Maxillofac Implants. 2004 Jan-Feb;19(1):124-32. PMid:14982365.
21 Breeding LC, Dixon DL, Nelson EW, Tietge ID. Torque required to loosen single- tooth implant abutment screws before and after simulated function. Int J Prosthodont. 1993 Sep-Oct;6(5):435-9. PMid:8297452.
22 Jemt T. In vivo measurements of precision of fit involving implant-supported prosthesis in the edentulous jaw. Int J Oral Maxillofac Implants. 1996 Mar-Apr;11(2):151-8. PMid:8666445.
23 Calandriello R, Tomatis M. Simpliflied treatment of the atrophic posterior maxilla via immediate/early function tilted implants: a prospective 1-year clinical study. Clin Implant Dent Relat Res. 2005;7(Suppl 1):S1-12.
24 Rodriguez AM, Aquilino SA, Lund PS. Cantilever and implant biomechanics: a review of the literature - part 2. J Prosthodont. 1994 Jun;3(2):114-8.
25 Rubo JH, Souza EAC. Finite element analysis of stress in bone adjacent to dental implants. J Oral Implantol. 2008;34(5):248-55.
26 Greco GD, Jansen WC, Landre Júnior J, Seraidarian PI. Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture. J Appl Oral Sci. 2009 Sep-Oct;17(5):515-20.
Submitted date:
07/02/2020
Accepted date:
12/15/2020