Mounting casts from removable prostheses in semi adjustable articulator

Montagem de modelos de próteses removíveis em articulador semi-ajustável

Cartagena, Andrés Felipe; Figuerôa, Rosana Marques Silva; Jorge, Janaina Habib; Urban, Vanessa Migliorini; Bombarda, Nara Hellen Campanha

Downloads: 4
Views: 1243

Abstract

Articulating preliminary or working casts in semiadjustable articulators is one of the most important procedures in the prosthetic rehabilitation of partially and fully edentulous patients. Objective: This work described the several steps involving mounting casts in semiadjustable articulator in cases of two patients presenting partial and fully edentulous arcs. Material and method: It was discussed the recommended material and techniques for recording the maxilomandibular positions, including a range of situations different from the presented cases. Conclusion: The fitting of models of the edentulous patients in articulator is of great importance and presents a wide range of indication according to different situations.

Keywords

Denture, complete, denture, partial, dental articulators.

Resumo

O relacionamento dos modelos de diagnóstico ou de trabalho em articulador semi-ajustável é um dos procedimentos mais importantes no tratamento reabilitador com próteses removíveis parciais ou totais. Objetivo: Este trabalho descreve as diversas etapas da montagem em articulador semi-ajustável em situações de dois pacientes com arcos parcial ou totalmente edêntulos. Material e método: Foram discutidos os materiais e técnicas indicadas para registro das relações intermaxilares, inclusive em situações diferentes dos casos apresentados. Conclusão: A montagem de modelos de pacientes parcialmente edêntulos em articulador é de grande importância e apresenta uma ampla variação de indicação de acordo com diferentes situações.

Palavras-chave

Prótese total, prótese parcial, articuladores dentários.

References



1. Zarb GA, Bolender CL, Eckert SE, Jacob RF, Fenton AH, Mericske-Stern R. Tratamento protético para os pacientes edêntulos – próteses totais convencionais e implantossuportadas. São Paulo: Livraria Santos Editora; 2006.

2. Watanabe MT. Dentaduras funcionales. México: Universidade Nacional Autônoma de México; 1988.

3. Akerly WB. A combination impression and occlusal registration technique for extension-base removable partial dentures. J Prosthet Dent. 1978;39:226-9. http://dx.doi.org/10.1016/S0022-3913(78)80026-2

4. McGill ST, Holmes JR. Mounting partially edentulous casts. Oper Dent. 2010;35:592-5. PMid:20945752. http://dx.doi.org/10.2341/10- 136-T

5. Ockert-Eriksson G, Eriksson A, Lockowandt P, Eriksson O. Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship. Int J Prosthodont. 2000;13:152-8. PMid:11203625.

6. Bezzon OL, Orsi IA. An interocclusal record made of a combination of wax and acrylic resin. J Prosthet Dent. 1994;72:334-6. http:// dx.doi.org/10.1016/0022-3913(94)90350-6

7. Dixon DL. Overview of articulation materials and methods for the prosthodontic patient. J Prosthet Dent. 2000;83:235-47. Review. http:// dx.doi.org/10.1016/S0022-3913(00)80017-7

8. Tripodakis AP, Vergos VK, Tsoutsos AG. Evaluation of the accuracy of interocclusal records in relation to two recording techniques. J Prosthet Dent. 1997;77:141-6. http://dx.doi.org/10.1016/S0022-3913(97)70227-0

9. McGivney GP, Castleberry DJ. Prótese parcial removivel de McCracken. São Paulo: Artes Médicas; 1994.

10. Lundquist DO, Fiebiger GE. Registrations for relating the mandibular cast to the maxillary cast based on Kennedy’s classification system. J Prosthet Dent. 1976;35:371-5. http://dx.doi.org/10.1016/0022-3913(76)90002-0

11. Greco GD, Fialho DL, Lana ACC, Jansen WC. Avaliação das dimensões programáveis dos articuladores semi-ajustáveis. Arq Odontol. 2008;44:19-24.

12. Mezzomo E, Suzuki RM. Reabilitação oral contemporânea. São Paulo: Livraria Santos Editora; 2006.

13. Pleasure MA. Correct vertical dimension and freeway space. J Am Dent Assoc. 1951;43:160-3. PMid:14850211.

14. Turrell AJ. Clinical assessment of vertical dimension. 1972. J Prosthet Dent. 2006;96:79-83. PMid:16911882. http://dx.doi.org/10.1016/j. prosdent.2006.05.015

15. Silverman MM. The speaking method in measuring vertical dimension. 1952. J Prosthet Dent. 2001;85:427-31. PMid:11357066. http:// dx.doi.org/10.1067/mpr.2001.116139

16. Bissasu M. Use of the tongue for recording centric relation for edentulous patients. J Prosthet Dent. 1999;82:369-70. http://dx.doi. org/10.1016/S0022-3913(99)70097-1

17. Shanahan TE. Physiologic vertical dimension and centric relation. 1956. J Prosthet Dent. 2004;91:206-9. PMid:15060486. http://dx.doi. org/10.1016/j.prosdent.2003.09.002

18. Davies SJ, Gray RM, McCord JF. Good occlusal practice in removable prosthodontics. Br Dent J. 2001;191:491-4, 497-502. Erratum in: Br Dent J 2001;191:670. PMid:11726062. http://dx.doi.org/10.1038/sj.bdj.4801215a

19. Rahn AO, Ivanhoe JR, Plummer KD. Textbook of complete dentures. Shelton: People’s Medical Publishing House; 2009.

20. Saunders TR, Gillis RE Jr, Desjardins RP. The maxillary complete denture opposing the mandibular bilateral distal-extension partial denture: treatment considerations. J Prosthet Dent. 1979;41:124-8. http://dx.doi.org/10.1016/0022-3913(79)90292-0

21. Zanetti GR, Zanetti LSS, Peçanha MM, Borges-Filho FF, Castro GC. Guia cirúrgico modificado para tuberoplastia em pacientes com Síndrome da Combinação. Rev Odontol UNESP. 2010;39:131-5.

22. Kliemann C, Oliveira W. Manual de prótese parcial removível. São Paulo: Livraria Santos Editora; 2009. p. 183-97.

23. Strohaver RA. A comparison of articulator mountings made with centric relation and myocentric position records. J Prosthet Dent. 1972;28:379-90. http://dx.doi.org/10.1016/0022-3913(72)90239-9

24. Beckett LS. Accurate occlusal relations in partial denture construction. J Prosthet Dent. 1954;4:487-95. http://dx.doi.org/10.1016/0022- 3913(54)90006-2

25. Ziebert GJ, Balthazar-Hart Y. Stabilized baseplate technique for interocclusal records. J Prosthet Dent. 1984;52:606-8. http://dx.doi. org/10.1016/0022-3913(84)90358-5

26. Ercoli C, Graser GN, Tallents RH, Galindo D. Face-bow record without a third point of reference: theoretical considerations and an alternative technique. J Prosthet Dent. 1999;82:237-41. http://dx.doi.org/10.1016/S0022-3913(99)70163-0

27. Freilich MA, Altieri JV, Wahle JJ. Principles for selecting interocclusal records for articulation of dentate and partially dentate casts. J Prosthet Dent. 1992;68:361-7. Review. http://dx.doi.org/10.1016/0022-3913(92)90346-C

28. McCracken WL. A philosophy of partial denture treatment. J Prosthet Dent. 1963;13:889-900. http://dx.doi.org/10.1016/0022- 3913(63)90232-4