Revista de Odontologia da UNESP
https://revodontolunesp.com.br/article/5880175b7f8c9d0a098b46af
Revista de Odontologia da UNESP
Original Article

Grampos de retenção para prótese parcial removível. Análise da resistência à flexão em função de- grampos, ligas e técnicas de fusão

Retentive clasps for removable partial denture. Analysis of the flexural strength in function of clasps, alloys, and casting techniques

Giampaolo, E.T.; Leonardi, P.; Cucci, A.L.M.; Fuller, J.B.

Downloads: 5
Views: 1981

Resumo

As ligas do sistema cobalto-cromo têm sido utilizadas para a confecção de estruturas metálicas de prótese parcial removível. No entanto, problemas com relação ao seu comportamento clínico, como a perda de retenção em curto espaço de tempo, motivou-nos a estudar três ligas deste sistema: Biosil (L1) Steldent (L2) e Duracrom (L3); três comprimentos de grampos: 13 mm (G1) 15 mm (G2) e 17 mm (G3), mantendo constante a proporção dois entre a largura e espessura, e duas técnicas de fusão: oxigênio-gás (F1) e oxigênio-acetileno (F2). Os grampos foram confeccionados através de matrizes, para obtençâo de padrões sempre com as mesmas dimensões, para cada condição. As técnicas de fusão foram as recomendadas pelos fabricantes, com exceção da liga Steldent. Os corpos de provaforam testados em uma máquina de ensaios cíclicos, que realizava inserções e remoções, a qual possuía um contador de giros, que permitia a visualização do número de ciclos realizados pelos grampos. Além disso, a máquina apresentava um sensor, que desligava todo o sistema quando ocorria a perda de retenção. Os resultados obtidos foram submetidos à analise estatística e as conclusões foram as seguintes: 1. As ligas analisadas tiveram comportamentos diferentes e a ordem decrescente de resistência à flexão foi: L3 (Duracrom), L1 (Biosil) e L2 (Steldent). 2. Os grampos estudados comportam-se diferentemente e a ordem decrescente de resistência à flexão ocorreu nas seguintes dimensões de grampos: G2 (2:1/15 mm), G3 (2:1/17 mm) e GI (2:1/13 mm). 3. A fonte de fusão F2 (oxigênio-acetileno) permitiu obterem-se valores de resistência à flexão aproximadamente 100% maiores do que os obtidos na F1 (oxigênio- gás).

Palavras-chave

Grampos de retenção, ligas, técnicas de fusão

Abstract

The alloys of the cobalt-chromium system, due to their favourable properties, have been utilized to the conffection of metallic structure of removable partial denture. Therefore, problems related to its clinic behaviour, as loss of retention upon a short period, induced us to study three alloys of this system: Biosil (L1), Steldent (L2), and Duracrom (L3); three length of clasps: 13 mm (G1), 15 mm (G2) and 17 mm (G3) keeping the proportion two constant between width and thickness and two casting techiniques: oxigen-gas (F1) and oxigen-acetylene (F2). The clasps were manufactured through matrix, for the obtain of patterns always with the same dimension, for each condition. The casting techniques were the recommended by manufacturer, exception to the Steldent alloy. The test pieces were tested upon an assay dclic machine, with a counter of cycles which made insertions and removals allowing the visualization of the number of cycles made by the clasps. Moreover, this machine had a sensor which turned the system off when a loss of retention occurred. The obtained results were submitted to statistical analysis and the conclusions were: 1. The analysed alloys had different behaviors and the decreasing sequence due to flexion resistance was: L3 (Duracrom), L1 (Biosil), and L2 (Steldent); 2. The behaviours of the analysed clasps were different and the decreasing sequence of resistance due to flexion occurred upon the following dimension of clasps: G2 (2:1/15 mm), G3 (2:1/17 mm) and G1 (2:1/13 mm); 3. The casting technique F2 (oxigen-acetylene) showed resistance due to flexion's values approximately 100% larger than those obtained for F1(oxigen- gas).

Keywords

Retentive clasps, alloys, casting techniques

References



1. ASGAR, K. et alo A new alloy for partial dentures. J. prosthet. Dent., v. 23, p. 36-43, 1970.

2. BATES, J.F. Retention of cobalt-chromium partial dentures. Dent. Pract., v. 14, p. 168-71, 1963.

3. BATES, J. F. Cast clasps for partial dentures./nt. dento J., v. 13, p. 610-14, 1963.

4. BATES, J.F. Studies related to the fracture of partial dentures. Flexural fatigue of a cobalt-chromium alIoy. Br. dent, J., v. 118, p. 532-37, 1965.

5. BATES, J. F. The mechanical properties of the cobalt-chromium alloys and their relation to partial denture designo Br. dento J., v. 119, p. 389-96, 1965.

6. BATES, J. F. Studies related to the fracture of partial dentures. The functional strain in cobalt-chromium dentures: a preliminary report. Br. dento J., v. 120, p. 79-83, 1966.

7. BATES, J. F. Studies on the retention of cobalt-chromium partial denture. Br. dento J., v. 125, p. 97-102, 1968.

8. BATES, J. F. Retention of partial dentures. Br. dento J., v. 149, p. 171-4, 1980.

9. BLATTERFEIN, L. A study of partial denture clasping. J. Am. Dent. Assoe., v. 43, p. 169-85, 1951.

10. BRUDVIK, J. S., WORMLEY, J. H. Construction techniques for wrought- wire retentive clasp arms as related to clasp flexibility. J. prosthet. Dent., v. 30, p. 769-74, 1973.

11. HARCOURT, H.J. The effects of variation in cooling rates and heat treatment on cobalt-chromium alloys. Br. Dent. J., v. 116, p. 475-83, 1964.

12. LEWIS, A. J. The influence of the refractory investment on the development of porosity in cast structures.Aust. dent.J., v. 22, p. 455-57,1977.

13. MILECK, A. Ligas de cromo-cobalto utilizadas em próteses parciais removrveis: estudo de algumas propriedades. Piracicaba: UNICAMP, 1967. Tese (Doutorado) - Faculdade de Odontologia, Universidade de Campinas.

14. MOHAMMED, H., ASGAR, K. A new dental superalloy system: I. Theory and alIoy designo J. dento Resp., v. 52, p. 136-44, 1973.

15. PASCOE, D.F., WIMMER, J.A radiographic technique for the detection of internal defects in dental casting.J.prosthet. Dent., v. 39, p. 150-57, 1978.

16. PHILLIPS, R.W. Materiais dentários de Skinner. 8. ed., Rio de Janeiro: Interamericana, 1984, p. 401-07.
5880175b7f8c9d0a098b46af rou Articles
Links & Downloads

Rev. odontol. UNESP

Share this page
Page Sections