Revista de Odontologia da UNESP
https://revodontolunesp.com.br/journal/rou/article/doi/10.1590/1807-2577.21215
Revista de Odontologia da UNESP
Original Article

Influence of diameter and intraradicular post in the stress distribution. Finite element analysis

Influência do diâmetro e do retentor intrarradicular na distribuição de tensões. Análise pelo método dos elementos finitos

Lemos, Cleidiel Aparecido Araújo; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Mello, Carol Cantieri; Verri, Fellippo Ramos; Pellizzer, Eduardo Piza; Mazaro, José Vitor Quinelli

Downloads: 2
Views: 1040

Abstract

Introduction: The biomechanical behavior of endodontically treated teeth depending on the selected restorative material and tooth situation to be restored. Objective: To analyze by the two-dimensional finite element method the biomechanical behavior of different diameters in intraradicular posts and teeth with coronal remaining of 2mm. Material and method: Six models were made with three types of posts, as follows: Glass fiber post, carbon fiber post, and cast metal post, both with diameter # 1 (1.1 mm in diameter) and # 2 (1.3 mm of diameter). The modeling was performed using the Rhinoceros 4.0 program. The FEMAP 10.2 and NEiNastran 9.2 programs were used to develop finite element models. The loading used was 100N for axial and oblique forces. The results were visualized using the von Mises stress map. The statistical analysis was made using analysis of variance (ANOVA) and Tukey post-test, with a significance level of 5%. Result: The oblique loading stress values were higher than the axial loading (p<0.001) for both situations. The glass fiber post showed the lowest concentrations of stress on both loads (p<0.001). The carbon fiber post presented significant difference compared to the cast metal post, only in the oblique load (p=0.007). The diameter did not increase the stress of the evaluated posts (p=0.302). Conclusion: The fiber posts were more favorable for restoration of endodontically treated teeth; the increase of diameter did not influence the increase of tension; the oblique load was more harmful for both posts and tooth structure.

Keywords

Dental prosthesis, post and core technique, denture partial fixed.

Resumo

Introdução: O comportamento biomecânico de dentes tratados endodonticamente é variável conforme o material restaurador selecionado e situação do dente a ser restaurado. Objetivo: Analisar por meio do método dos elementos finitos bidimensional o comportamento biomecânico de diferentes retentores intrarradiculares e diâmetros em dentes com 2mm de remanescente coronário. Material e método: Foram confeccionados seis modelos com três tipo de retentores: pino de fibra de vidro, pino de fibra de carbono e núcleo metálico fundido, ambos com diâmetro #1 (1,1mm de diâmetro) e #2 (1,3mm de diâmetro). A modelagem foi realizada através do programa Rhinoceros 4.0, e em seguida nos programas FEMAP 10.2 e NeiNastran 9.2 para desenvolvimento d os modelos de elementos finitos. Nos carregamentos foram utilizadas forças de 100N axial e oblíquo. Os resultados foram visualizados pelo mapa de tensão von Mises, e pela análise de variância (ANOVA) e pós-teste Tukey, com nível de significância à 5%. Resultado: O carregamento oblíquo apresentou maiores valores de tensões (p<0,001). O pino de fibra de vidro apresentou menores concentrações de tensões em ambos os carregamentos (p<0,001). O pino de fibra de carbono apresentou diferença significativa em relação ao núcleo metálico somente no carregamento oblíquo (p=0,007). O  diâmetro não influenciou para o aumento de tensões dos retentores avaliados (p=0,302). Conclusão: Os pinos de fibras são mais favoráveis para restaurações de dentes tratados endodonticamente; O aumento do diâmetro não influenciou no aumento de tensões; A carga oblíqua é mais prejudicial à tanto para o retentor quanto para a estrutura dentária.

Palavras-chave

Prótese dentária, técnica para retentor intrarradicular, prótese parcial fixa.

References

1. Al-Omiri MK, Mahmoud AA, Rayyan MR, Abu-Hammad O. Fracture resistance of teeth restored with post-retained restorations: an overview. J Endod. 2010 Sep;36(9):1439-49. http://dx.doi.org/10.1016/j.joen.2010.06.005. PMid:20728706.

2. Verissimo C, Simamoto PC Jr, Soares CJ, Noritomi PY, Santos-Filho PC. Effect of the crown, post, and remaining coronal dentin on the biomechanical behavior of endodontically treated maxillary central incisors. J Prosthet Dent. 2014 Mar;111(3):234-46. http://dx.doi.org/10.1016/j.prosdent.2013.07.006. PMid:24199605.

3. Zhou L, Wang Q. Comparison of fracture resistance between cast posts and fiber posts: a meta-analysis of literature.J Endod. 2013 Jan;39(1):11-5. http://dx.doi.org/10.1016/j.joen.2012.09.026. PMid:23228250.

4. Torbjörner A, Fransson B. Biomechanical aspects of prosthetic treatment of structurally compromised teeth. Int J Prosthodont. 2004 MarApr;17(2):135-41. PMid:15119862.

5. Clavijo VG, Reis JM, Kabbach W, Silva AL, Oliveira OB Jr, Andrade MF. Fracture strength of flared bovine roots restored with different intraradicular posts. J Appl Oral Sci. 2009 Nov-Dec;17(6):574-8. http://dx.doi.org/10.1590/S1678-77572009000600007. PMid:20027429.

6. Figueiredo FE, Martins-Filho PR, Faria e Silva AL. Do metal post-retained restorations result in more root fractures than fiber post-retained restorations? A systematic review and meta-analysis. J Endod. 2015 Mar;41(3):309-16. http://dx.doi.org/10.1016/j.joen.2014.10.006. PMid:25459568.

7. Sarkis-Onofre R, Jacinto RC, Boscato N, Cenci MS, Pereira-Cenci T. Cast metal vs. glass fibre posts: a randomized controlled trial with up to 3 years of follow up. J Dent. 2014 May;42(5):582-7. http://dx.doi.org/10.1016/j.jdent.2014.02.003. PMid:24530920.

8. Durmus G, Oyar P. Effects of post core materials on stress distribution in the restoration of mandibular second premolars: a finite element analysis. J Prosthet Dent. 2014 Sep;112(3):547-54. http://dx.doi.org/10.1016/j.prosdent.2013.12.006. PMid:24630398.

9. Sumitha M, Kothandaraman R, Sekar M. Evaluation of post-surface conditioning to improve interfacial adhesion in post-core restorations. J Conserv Dent. 2011 Jan;14(1):28-31. http://dx.doi.org/10.4103/0972-0707.80728. PMid:21691501.

10. Barcellos RR, Correia DP, Farina AP, Mesquita MF, Ferraz CC, Cecchin D. Fracture resistance of endodontically treated teeth restored with intra-radicular post: the effects of post system and dentine thickness. J Biomech. 2013 Oct;46(15):2572-7. http://dx.doi.org/10.1016/j.jbiomech.2013.08.016. PMid:24055192.

11. Chang YH, Lin WH, Kuo WC, Chang CY, Lin CL. Mechanical interactions of cuspal-coverage designs and cement thickness in a cuspreplacing ceramic premolar restoration: a finite element study. Med Biol Eng Comput. 2009 Apr;47(4):367-74. http://dx.doi.org/10.1007/s11517-008-0379-y. PMid:18679734.

12. Ko CC, Chu CS, Chung KH, Lee MC. Effects of posts on dentin stress distribution in pulpless teeth. J Prosthet Dent. 1992 Sep;68(3):421-7. http://dx.doi.org/10.1016/0022-3913(92)90404-X. PMid:1432755.

13. Genovese K, Lamberti L, Pappalettere C. Finite element analysis of a new customized composite post system for endodontically treated teeth. J Biomech. 2005 Dec;38(12):2375-89. http://dx.doi.org/10.1016/j.jbiomech.2004.10.009. PMid:16214485.

14. Chuang SF, Yaman P, Herrero A, Dennison JB, Chang CH. Influence of post material and length on endodontically treated incisors: an in vitro and finite element study.J Prosthet Dent. 2010 Dec;104(6):379-88. http://dx.doi.org/10.1016/S0022-3913(10)60171-0. PMid:21095401.

15. Coelho CS, Biffi JC, Silva GR, Abrahão A, Campos RE, Soares CJ. Finite element analysis of weakened roots restored with composite resin and posts. Dent Mater J. 2009 Nov;28(6):671-8. http://dx.doi.org/10.4012/dmj.28.671. PMid:20019417.

16. Imanishi A, Nakamura T, Ohyama T, Nakamura T. 3-D Finite element analysis of all-ceramic posterior crowns. J Oral Rehabil. 2003 Aug;30(8):818-22. http://dx.doi.org/10.1046/j.1365-2842.2003.01123.x. PMid:12880406.

17. Torres-Sanchez C, Montoya-Salazar V, Cordoba P, Velez C, Guzman-Duran A, Gutierrez-Perez JL, et al. Fracture resistance of endodontically treated teeth restored with glass fiber reinforced posts and cast gold post and cores cemented with three cements. J Prosthet Dent. 2013 Aug;110(2):127-33. http://dx.doi.org/10.1016/S0022-3913(13)60352-2. PMid:23929374.

18. Santos AF, Meira JB, Tanaka CB, Xavier TA, Ballester RY, Lima RG, et al. Can fiber posts increase root stresses and reduce fracture? J Dent Res. 2010 Jun;89(6):587-91. http://dx.doi.org/10.1177/0022034510363382. PMid:20348486.

19. Dejak B, Mlotkowski A. Finite element analysis of strength and adhesion of cast posts compared to glass fiber-reinforced composite resin posts in anterior teeth. J Prosthet Dent. 2011 Feb;105(2):115-26. http://dx.doi.org/10.1016/S0022-3913(11)60011-5. PMid:21262409.

20. Silva NR, Raposo LH, VersluisA, Fernandes-NetoAJ, Soares CJ. The effect of post, core, crown type, and ferrule presence on the biomechanical behavior of endodontically treated bovine anterior teeth. J Prosthet Dent. 2010 Nov;104(5):306-17. http://dx.doi.org/10.1016/S0022-3913(10)60146-1. PMid:20970537.

21. Kaya BM, Ergun G. The effect of post length and core material on root fracture with respect to different post materials. Acta Odontol Scand. 2013 Sep;71(5):1063-70. http://dx.doi.org/10.3109/00016357.2012.741706. PMid:23163305.

22. Wang CH, Du JK, Li HY, Chang HC, Chen KK. Factorial analysis of variables influencing mechanical characteristics of a post used to restore a root filled premolar using the finite element stress analysis combined with the Taguchi method. Int Endod J. 2015 In press. http://dx.doi.org/10.1111/iej.12499. PMid:26172249.

23. Romeed SA, Fok SL, Wilson NH. A comparison of 2D and 3D finite element analysis of a restored tooth. J Oral Rehabil. 2006 Mar;33(3):209-15. http://dx.doi.org/10.1111/j.1365-2842.2005.01552.x. PMid:16512887.

24. Poiate IA, VasconcellosAB, Mori M, Poiate E Jr. 2D and 3D finite element analysis of central incisor generated by computerized tomography. Comput Methods Programs Biomed. 2011 Nov;104(2):292-9. http://dx.doi.org/10.1016/j.cmpb.2011.03.017. PMid:21531473.

25. Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24(2):80-8. http://dx.doi.org/10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO;2. PMid:9835834.