Revista de Odontologia da UNESP
https://revodontolunesp.com.br/article/5880174c7f8c9d0a098b4669
Revista de Odontologia da UNESP
Original Article

Efeitos de materiais e distâncias na precisão de reprodução de molde e modelos para prótese parcial removível

Materials and distances effects in the reproduction accuracy of molds and models in partial removable prosthodontics

Cucci, A.L.M.; Fuller, J.B.

Downloads: 2
Views: 980

Resumo

Foi estudada a alteração dimensional de 3 tipos de materiais de moldagem e de 1 material para modelo. Os materiais de moldagem e respectivas técnicas de espatulação empregadas foram: hidrocolóide irreversível Xantalgín - espatulação convencional; polisulfeto Permlastic pesado e leve - dupla espatulação; polisulfeto Permlastic regular e Silicona Xantopren - espatulação única; siliconas Optosil/Xantopren - dupla espatulação e dupla moldagem. O gesso pedra melhorado Vel-Mixfoi o material para modelo empregado. Utilizou-se um modelo padrão de aço inoxidável, simulando um arco parcialmente desdentado possuindo 6 pontos de referências: A, B, C, D, E e F. As distâncias entre os pontos AB, BC, DE, EF e BE foram mensuradas nos moldes e modelos através de um projetor de perfil marca Nikon, modelo 6C e comparadas com as do modelo padrão. Após a análise estatística, concluiu-se: a) os moldes obtidos a partir dos polisulfetos pesado e leve, regular e do hidrocolóide irreversível foram os que reproduziram as medidas do modelo padrão com as menores diferenças. b) os modelos obtidos a partir dos modelos de Optosil - Xantopren - nas técnicas de dupla espatulação e dupla moldagem apresentaram os melhores resultados na reprodução do modelo padrão. c) das distâncias analisadas nos moldes, as de menor dimensão foram reproduzidas com menores alterações em relação ao modelo padrão. d) a distância foi reproduzida com maior alteração nos moldes e modelos.

Palavras-chave

Precisão de reprodução, materiais de moldagem, material de modelo, alteração dimensional

Abstract

It was estudied the accuracy of 3 impression materials and 1 stone. The impression materiais and mixing technique employed were: irreversible hydrocolloid Xantalgin conventional mixing; Polysulfide Permiastic, heavy and light bodied - double mix; Permlastic regular bodied and silicone Xantopren - single mix; silicones Optosil/Xantopren - double mix and double impression. The stone employed was Vel-Mix. The stainless steel master model utilized simulates one arch partially edentulous and have 6 points: A, B, C, D, E and F. The distances AB, BC, DE, EF and BE were measured on the models by a profile projector Nikon, and compared with the sarne distances in the master model. The authors concluded that: a) the most accurate impressions were produced from polysulfide heavy and light bodied, regular bodied and irreversible hydrocolloid; b) the most accurate models were produced from the impressions obtained with Optosil/Xantopren; c) the distances AB and EF were reproduced in the impressions with lower values of dimensional changes; d) the distance BE were reproduced, both in impressions and models, with greater values of dimensional changes.

Keywords

Accuracy, impression materials, stone dimensional, change

References



1. FUSAYAMA, T.; IWAKU, M.; DAITO, K.; KUROSAKI, N. & TAKATSU, T. Accuracy of the laminated single impression tecnique with silicone materiaIs. J. prosth. Dent., 32: 270-6, 1974.

2. HOLLENBACK, G. M. - A study of the physicaI properties of elastic impression materiaIs (the linear and over-all accuracy of reversible and irreversible hydrocolloids). Part IV. J. South Calí/. dento Ass., 31: 403-8, 1963.

3. MILLER, Jr., W. A. C.; HANSEN, W. C.; DICKSON, G. and SWEENEY, W. T.- Physical properties of synthetic - ruber - base dentaI impression materiaIs. J. amo dento Ass., 60: 211-23, 1960.

4. NEWMAN, A. & WILLIAMS, J. O. - Die materiaIs for inlay, crown and bridge work. Br. dento J., 127: 415-20, 1969.

5. SCHNELL, R. J. & PHILLIPS, R. W. - Dimensional stability of rubber base impressions and certain other factors.affecting accuracy. J. amo dento Ass., 57: 39-48, 1958.

6. SKINNER, E. W. - Propriedades y manipulación de los materiaIes de impressión a base de mercaptanos y siliconas. Odont. clin. Norte Am., 6: 1l3-87, 1960.

7. SKINNER, E. W.; COOPER, E. N. & BECK, F. E. - Reversible and irreversible hydrocolloid impression materiaIs. J. amo dento Ass., 40: 196-207, 1950.

8. STACKHOUSE, Jr., J. A. - The accuracy of stone dies made from rubber impression materiaIs. J. prosth. Dent., 24: 377-86, 1970.
5880174c7f8c9d0a098b4669 rou Articles
Links & Downloads

Rev. odontol. UNESP

Share this page
Page Sections